The MistTerminator (MT) is a modular filtration system that captures oil smoke/mist. For handling oil mist, you shall choose the MT-31. If you need to handle both oil mist and oil smoke you require MT-32 that is equipped with additional HEPA filter. All MT filter units and filter banks are modular and can be tailored to your needs.
Processes and applications
• Cutting, boring, drilling, honing using various metalworking equipment and CNC machine tools
• Cold pressing and stamping operations
• Hardening and wet grinding of metal
Restrictions
Do not use the MT-31/MT-32 and MT-41/MT-42 for the following applications or in the following circumstances:
• Aluminium laser cutting
• Arc-air gouging
• Paint mist
• Extraction of hot gases (more than 45 °C/113 °F continuously)
- Intended for 1 – 2 work shift, light mode (processing parts at low and medium speed)
- Suitable for processes involving contamination of coolant in the form of a thick sludge of metallic particles and burnt oil
- Handles combined wet and dry metal processing
- Not suitable for oils with a flash point below 150 °C (300 °F)
- Maximum initial oil concentration is 30 — 40 mg/m<sup>3</sup>
- Filters have pressure indicator showing clogging level
- Prepared for direct mounting of the fan on the filter
- New mechanism for quick filter replacement during scheduled maintenance
- Two input sockets for easy alternative duct installation
Description | МT-31 art. 5290 | МT-32 art. 5293 |
---|---|---|
Airflow, m3/hour, max | 3,000 | 3,000 |
Pressure loss (for calculation purposes), Pa | 700 | 1,200 |
Weight, kg | 98 | 134 |
Filtration class: DIN EN 779(F9)/ DIN EN 1822 (Н13); ASHRAE 52.2(MERV15/ME V16) | F9/MERV15 | H13/MERV16 |
Negative pressure (max.), Pa | 4,000 | |
Oil receiver capacity (makes part of the delivery package), l | 8 | |
Inlet diameter, mm | 2x250 (1 inlet connection piece and 1 plug in the package) | |
Diameter of connecting flange sFF-DUCT/250 airduct (to be ordered additionally), mm | 250 | |
sFF-FAN-B connecting flange (for VMA-3000-4700 fans) | 250 | |
BFMT-31 Bag filter (for MT-31, MT-32) | 500 | |
OC-1 Filter catridge, 1st stage. Self-draining (for MT-41, MT-42) | 500 | |
OC-2 Filter catridge, 2st stage. Self-draining (for MT-41, MT-42) | 800 | |
HFMT-3. HEPA filter (for MT-32, MT-42) | 800 | |
Capacity and amount of OilContainer oil receivers (makes part of the delivery package) | 8 l /1 piece |
- Filter body, preassembled with all filter elements and pre-filters
- 250 mm inlet nipple (on the inlet module)
- 250 mm cover (on the inlet module)
- 250 mm outlet for direct installation of the fan (on the top cover of the filter)
ATTENTION! FOLLOWING PARTS ARE TO BE ORDERED SEPARATELY:
- Extraction fan
- Pressure adapter for the fan connection to round section duct line
- Silencer
- Fan starter
- Connection flange
- Outlet nipple for connection to the extraction fan
OTHER PRODUCTS
MT 41/42 Stationary self-draining filter for oilmist/smoke. Suitable for clean low viscosity oil based coolants. For continuous 2-3 shifts operation.
Oil mist pre-separator Pre-separator is intended for removal of mist and vapors of oil and emulsion
ESPO Wall hanging electrostatic filter for oil smoke. For high viscosity oil-based coolants with an oil concentration of 5% and more. Requires an appropriate fan.
MM Small and compact oil mist filter. Installed directly on or beside the machine. Suitable for a wide range of oil-based coolants.